A comprehensive analysis of the technology supply chain for United States water infrastructure reveals that the sector faces a significantly broader security risk than previously documented by federal agencies. A study conducted by the exposure management firm Securin, which cross-referenced data from the Cybersecurity and Infrastructure Security Agency (CISA), the Environmental Protection Agency (EPA), the FBI, and WaterISAC, identified nearly double the number of vulnerabilities in water-sector technology vendors than are currently tracked in public federal records.
The investigation highlights a critical gap between official vulnerability tracking and the reality of operational technology (OT) security. While the federal government has cataloged 1,792 vulnerabilities known to have been exploited in cyberattacks, the Securin study uncovered 20 additional exploited flaws that are absent from CISA’s Known Exploited Vulnerabilities (KEV) catalog. This discrepancy suggests that reliance on official advisory lists may provide a false sense of security for utility operators, as the volume of security alerts does not necessarily correlate with the most pressing threats to physical infrastructure.
Five major vendors—Rockwell Automation, Advantech, Schneider Electric, Siemens, and ABB—were responsible for 191 of the 376 security advisories tagged for the water sector. Notably, while Advantech recorded the highest number of critical-rated vulnerabilities, none of the associated Common Vulnerabilities and Exposures (CVEs) appear in the federal KEV catalog. Conversely, some vendors with fewer official advisories remain highly susceptible to attacks that bypass software vulnerabilities entirely. For instance, Unitronics recorded only two water-tagged advisories, yet at least 75 of its controllers were compromised between late 2023 and early 2024 due to the use of default or missing passwords.
The findings underscore that attackers frequently circumvent the need for complex software exploits by targeting misconfigured, internet-facing hardware. A primary example of this occurred in July, when suspected Iran-linked actors targeted more than 100 water systems across at least 12 states. These intrusions utilized poorly secured, internet-connected programmable logic controllers (PLCs). Federal agencies have confirmed that these actors leveraged foreign-based IP addresses and third-party hosted infrastructure to access PLCs manufactured by Rockwell Automation, Schneider Electric, and Siemens.
The investigation identified specific technical vectors for these intrusions, noting that malicious traffic has been observed targeting standard industrial ports, including 44818, 2222, 102, and 502, as well as port 22 for modem access. Research indicates that as of mid-November, 791 Rockwell MicroLogix 1400 controllers remained exposed to the public internet. Furthermore, roughly 70 percent of exposed Rockwell controllers in the U.S. are connected via mobile carrier networks, often through cellular modems installed by third-party contractors that are frequently undocumented by the utility providers themselves.
These cellular modems represent a significant, often overlooked entry point for unauthorized access. Because these devices are frequently installed by external contractors without the knowledge of the utility’s IT department, they often lack sufficient security controls. The combination of an exposed cellular modem and a misconfigured controller creates an environment where attackers can gain entry without needing to exploit a specific software bug.
To mitigate these risks, security experts emphasize that utility providers must move beyond merely patching known CVEs. The recommended strategy involves conducting a comprehensive asset discovery to identify all cellular modems within the network environment, including those installed by third-party vendors. Once identified, these devices should be removed from direct exposure to the open internet and secured behind a gateway that mandates multifactor authentication.
Ultimately, the study suggests that the current focus on fixing publicized vulnerabilities may be misaligned with the tactics used by active threat actors. While utilities continue to allocate resources toward addressing documented software flaws, attackers are successfully gaining access through equipment that is either unknown to the organization or protected by inadequate, default credentials.