Broadcom has issued a security patch for a critical vulnerability in VMware vCenter Server, identified as CVE-2026-123890. The flaw, which carries a maximum CVSS severity score of 9.8, allows a remote, unauthenticated attacker to gain administrative access to the vCenter Server. This vulnerability affects vCenter Server, SDDC Manager, and VMware Tools for Windows, including deployments within VMware Cloud Foundation, vSphere Foundation, and various Telco Cloud platforms. Broadcom confirmed that there are no available workarounds, necessitating that organizations update to the versions specified in security advisory VMSA-2026-0009.
Security researchers from Google Threat Intelligence Group and Mandiant have linked the exploitation of this zero-day to a China-nexus espionage actor known as Armory Castle, formerly tracked as UNC5221. While Broadcom’s advisory does not explicitly mention in-the-wild exploitation, researchers have confirmed that the group has been actively leveraging the vulnerability since at least early September 2026. Evidence suggests the attackers may have possessed the capability to exploit this flaw as early as July 2026, based on the build timestamp of a custom exploit tool.
The attack chain observed by researchers demonstrates a sophisticated approach to lateral movement and persistence. The threat actors initially gained access to target environments by exploiting a separate zero-day vulnerability in BeyondTrust Remote Support, designated as CVE-2026-102764. From there, the group moved into internal Linux appliances that lacked endpoint detection and response (EDR) coverage. Once inside, they deployed a specialized Go-based exploit tool dubbed BONESAW to compromise the vCenter environment.
Upon gaining administrative control via BONESAW, the attackers created a new Single Sign-On (SSO) administrator account and extracted the vCenter directory database. This database contains the cryptographic keys necessary for signing login tokens. The attackers then utilized a second custom tool, SAWSNAKE, to pull these signing keys and forge SAML authentication tokens. This technique allowed the actors to bypass multi-factor authentication and impersonate any user within the system.
The scope of the intrusion extended beyond the vCenter management layer. The attackers targeted ESXi hosts to access virtual machine disks, from which they exfiltrated sensitive data, including Active Directory databases and Windows registry hives. This data was staged on the previously compromised BeyondTrust appliance before being exfiltrated from the network. Researchers noted that the campaign involved at least five previously undocumented malware families, underscoring the significant resources available to the Armory Castle group.
Broadcom has credited Mandiant with the discovery of CVE-2026-123890. Although the vulnerability shares some functional similarities with a previous authentication bypass flaw, CVE-2026-59309, Broadcom maintains that the two are distinct issues. The discovery of the BONESAW tool, which was used against systems already patched for the older vulnerability, indicates that the attackers likely developed the exploit for broader, long-term espionage operations.
In addition to applying the necessary patches, security analysts are urging organizations to conduct thorough threat hunting to identify potential evidence of prior compromise. Because the vCenter management interface can be used to disable built-in firewall protections, reactive patching alone may not be sufficient to remediate an environment that has already been breached.
To bolster defenses, experts recommend implementing more robust monitoring, such as the VCSA Hardening Logging Tool, which can restrict network access and filter outbound traffic. Indicators of compromise and YARA rules have been provided by security researchers to assist administrators in scanning their environments for the specific tools and techniques employed by Armory Castle. The incident highlights the ongoing challenge of securing centralized control planes against well-resourced adversaries who target systems that cannot easily support traditional EDR solutions.





